Sign up to join this community. The best answers are voted up and rise to the top. Stack Overflow for Teams — Collaborate and share knowledge with a private group. Create a free Team What is Teams? Learn more. Linux command line character limit Ask Question.
Asked 11 years, 3 months ago. Active 1 year, 10 months ago. Viewed 71k times. Improve this question. I do not understand the question. Are you interested in the limit of characters?
You need to state your question more clearly, else its just going to get closed. Boris That's because echo is a builtin. Add a comment. Active Oldest Votes. Improve this answer. Boris 6 6 bronze badges. David Spillett David Spillett Yes, but if using the Eclipse build system, this would have to be generated by the plugins, which is not the case.
In practical terms, extending is possible only by completely rewriting the classes, which is not practical, since keeping in sync with future CDT versions becomes too manually intensive. Hi Mike, are you sure that the new make is used? With your solution Eric, now i am able to build my project, but the clean function does not work. If I manually delete the debug folder, I can do a build from scratch no problem, but clean fails.
No matter what I do I get the following error:. Hi Andrew, I had that problem only once or twice, and it disappeared not sure why. Could it be that you have another rm present in your PATH settings on system level? It works fine now. This is not a great solution going forward, but it does hint at a lingering character limit issue. So the easy workaround is to delete the output folder e.
Thanks for your help with this, I will followup with the bug report if I have anything more to add. Did you install the build tools using the setup? Can you confirm that make. Yes, I installed the build tools using setup, renamed the old ones, and copied the new ones over exactly as described in the instructions.
This was extremely helpful, I just ran into this exact issue with KDS and luckily found your posting. This is super helpful, thank you for sharing. It worked great with KDS 2. Seems to be fine there, too! The command line is too long. Hi Alex, hmm, I can tell that for me using these new tools removed the problem.
But your command line looks like you are using something else than plain Windows cmd somehow? Installation fixed the linker issue but would not build a clean project.
Good point! I have not been running into this as for a long time I started to use forward slashes in my project settings whenever possible to keep things in sync with Linux. And the wizard in Eclipse seems to use forward slashes whenever possible too. Hi, I am running KDS3. I ran into this building error and downloaded 64 bits version.
It always crushed when I try to build project. Any solution for that?? Hi Yaran, I have not seen this with Windows 7 and 64bit. Same problem if you use the 32bit version of the tools? Followed the instructions to the letter. Not sure what is missing here but this is not working out as a solution. But v2. Is there a reason why not using v3.
I recommend that you install 3. Very simple. We are nearing production and it is late in the game to make a tool change unless absolutely necessary.
Tool updates are often a trade off between different bugs, as opposed to the elimination of all bugs, but your mileage may vary.
Generally each GNU ARM Eclipse binary packages installs in a separate folder, exactly to allow strict environments to return to a desired version in case new ones break any compatibility. However great job, thanks so much. Yes, it seems that with the most recent release more files are necessary, thanks for pointing this out. I had to also copy the. Using KSDK 1. Hi Mike, yes, this one was a nasty issue to identify. The good news is that the latest KDS v3.
After making the changes and not using Command Line, now I have another issue with createProcessFunction in Windows which has limitation of 32K characters.
I change the builder to external builder and selected the installed tools path in Builder Path Configuration. Are you using Kinetis Design Studio V3.
If not, you can give that one a try as it comes with the binaries included and works fine for me. In Command Prompt, the total length of EnvironmentVariable1 after you expand EnvironmentVariable2 and EnvironmentVariable3 can't contain more than characters:.
In a batch file, the total length of the following command line after you expand the parameters can't contain more than characters:. Even though the Win32 limitation for environment variables is 32, characters, Command Prompt ignores any environment variables that are inherited from the parent process and are longer than its own limitations of characters as appropriate to the operating system.
To work around the limitation, use one or more of the following methods, as appropriate to your situation:. Modify programs that require long command lines so that they use a file that contains the parameter information, and then include the name of the file in the command line.
For example, instead of using the ExecutableFile. ParameterN command line in a batch file, modify the program to use a command line that is similar to the following command line, where ParameterFile is a file that contains the required parameters parameter1 parameter ParameterN :.
Modify programs that use large environment variables so that the environment variables contain less than characters. For example, if the PATH environment variable contains more than characters, use one or more of the following methods to reduce the number of characters:. Feedback will be sent to Microsoft: By pressing the submit button, your feedback will be used to improve Microsoft products and services.
Privacy policy.
0コメント